Home        Product List         About the Company        Contact Us        News & Events         Online Store        

3-300MHz Phase Detector with Loop Filter

PDF Series
PDF-100 is a Phase/Frequency Detector with integrated Loop Filter. It operates with input frequency range from 3MHz to 300MHz, easy to use for Phase Looked Loop application.

Features:
• Input Frequency: 3 to 300MHz
• Output Frequency: -10 to +17dBm
• Integrated Loop Filter
• Directly Interface to FPS Series
• Directly Interface to VCO Series
• DC Power: 12V
• SMA Connector


Download Specifications

Product Spec »

Product Information
For more information about our products, please contact us directly at 301.838.4380 or email us at sales@shireeninc.com


Specifications

Electrical @ +25 °C, ZS = ZL = 50 Ohms
Parameter Unit Min Typical Max
Fin and Ref Input Frequency Range
MHz
3
300
Input Power Level

dBm

-10

+17

*Phase Noise
@1KHz Offset With
FPS-80-8 and VCO2050
Fo=2000MHz, Ref=25MHz

dBc/Hz
-85

*Phase Noise
@1KHz Offset With
FPS-12-13 and VCO3300
Fo=3300MHz, Ref=275MHz

dBc/Hz
-89
Loop Filter Bandwidth
KHz
10

Tuning Voltage Output Range

V

0.1

4.9
Input/Output VSWR
1.20:1/1.20:1

DC Power Supply

V
7
12
15

Supply Current

mA
175

*Phase Noise depends on VCO, reference and loop


Back to top »