Features & Benefits |
---|
|
How to buy this Product
- Type N Male for RG316 / RG174A-U / LMR100A / RFC100A
- Type N Male Right Angle for RG316 / RG174A-U / LMR100A / RFC100A
- Type N Female for RG316 / RG174A-U / LMR100A / RFC100A
- Type N Female Bulkhead for RG316 / RG174A-U / LMR100A / RFC100A
- Type N Female 4 Hole Flange 0.5″ for RG316 / RG174A-U / LMR100A / RFC100A
- Type N Female 4 Hole Flange 1″ for RG316 / RG174A-U / LMR100A / RFC100A
- Type N Female Bulkhead for 1mm cable
- Type N Male for RG58 / LMR195 / RFC195 / RG142 / RG400 / RG223
- Type N Male Right Angle for RG58 / LMR195 / RFC195 / RG142 / RG400 / RG223
- Reverse Polarity Type N Male for RG58 / LMR195 / RFC195 / RG142 / RG400 / RG223
- Type N Female for RG58 / LMR195 / RFC195 / RG142 / RG400 / RG223
- Type N Female Bulkhead for RG58 / LMR195 / RFC195 / RG142 / RG400 / RG223
- Type N Female 4 Hole Flange 1” for RG58 / LMR195 / RFC195 / RG142 / RG400 / RG223
- Type N Male – RG402
- Type N Female 4 Hole Flange for RG8x / LMR240 / RFC240
- Type N Male for RG8x / LMR240 / RFC240
- Type N Male Right Angle for RG8x / LMR240 / RFC240
- Type N Male Captivated for RG8x / LMR240 / RFC240
- Reverse Polarity Type N Male for RG8x / LMR240 / RFC240
- Type N Female for RG8x / LMR240 / RFC240
- Type N Female Bulkhead for RG8x / LMR240 / RFC240
- Type N Female Clamp for RG8x / LMR240 / RFC240
- Type N Male for LMR400 / RFC400 / RG213 / RG8U
- Type N Male Captivated for LMR400 / RFC400 / RG213 / RG8U
- Type N Male Right Angle for LMR400 / RFC400 / RG213 / RG8U
- Type N Male Silver Plated for LMR400 / RFC400 / RG213 / RG8U
- Type N Male Clamp for LMR400 / RFC400 / RG213 / RG8U
- Type N Female for LMR400 / RFC400 / RG213 / RG8U
- Type N Female Bulkhead for LMR400 / RFC400 / RG213 / RG8U
- RT Type N Male for LMR400 / RFC400 / RG213 / RG8U
- RT Type N Female for LMR400 / RFC400 / RG213 / RG8U
- Type N Male Hex for LMR600 / RFC600
- Type N Male for LMR600 / RFC600
- Type N Male Right Angle for LMR600 / RFC600
- Type N Female for LMR600 / RFC600
- Type N Male for 1/4 SuperFlex
- Type N Female Bulkhead for 1/4 SuperFlex
- Type N Male for 1/2 SuperFlex
- Type N Male for 1/2 Foam
- Type N Male for 7/8 Foam
- Type N Male Right Angle for 7/8 Foam
- Type N Female Bulkhead for RG402
Applications |
---|
|
Electrical | |
Impedance | 50 Ω |
Frequency Range | 0 – 11 GHz |
Voltage Rating | 1,500 volts peak |
VSWR | MIL-C-39012 straight connectors: 1.3 max 0-11 GHz MIL-C-39012 right angle connectors: 1.35 max 0-11 GHz |
Dielectric Withstanding Voltage | 2,500 volts rms |
Insulation Resistance | 5,000 MΩ minimum |
Center Contact Resistance | 1.0 mΩ |
Outer Contact Resistance | 0.2 mΩ |
RF Leakage | -90 dB minimum at 3 GHz |
Insertion Loss | .15 dB maximum at 10 GHz |
Mechanical | |
Mating | 5/8-24 threaded coupling |
Braid or Jacket Cable Affixment | All crimps: hex braid crimp Clamps: screw-thread nut and braid clamp |
Center Conductor Cable Affixment | Crimp: crimp or solder All others: solder only |
Captivated Contact | All crimps unless specified otherwise |
Cable Retention | Crimps: 60-120 lbs Clamps: 30-70 lbs |
Material | |
Male Contacts | Brass, silver or gold plated |
Female Contacts | Phosphorous bronze or beryllium copper, silver or gold plated |
Other Metal Parts | Brass with ASTROplate® finish; M39012 has silver finish |
Insulators | TFE, copolymer of styrene or glass-TFE (hermetic seal) |
Weatherproof Gaskets | Silicone rubber of synthetic rubber |
Crimp Ferrule | Copper |
Environmental | |
Temperature Range | TFE: -65°C to +165°C |
Weatherproof | All series N with gaskets are weatherproof |
Hermetic Seals | Pass helium leak test of 2×10-8 cc/sec |
Pressurized Shock | Compression seal MIL-STD-202, method 213 |
Vibration | MIL-STD-202, method 204, test condition B |
Moisture Resistance | MIL-STD-202, method 106 |
Corrosion | MIL-STD-202, method 101, test condition B |
Temperature Cycling | MIL-STD-202, method 102, test condition C |
Altitude | MIL-STD-202, method 105, test condition C |
Military | |
MIL-C-39012 MIL-A-55339 | Where applicable |
Note: These characteristics are typical but may not apply to all connectors.
Electrical | |
Impedance | 50 Ω |
Frequency Range | 11.0 GHz |
Return Loss | 33 dB (1-2 GHz) 28 dB (2-3 GHz) |
Operating Voltage | Maximum 707 rms |
Dielectric Withstanding Voltage | 2,000 vdc |
Insulation Resistance | 5,000 MΩ minimum |
Insertion Loss | .05 frequency GHz |
Shielding Effectiveness | Minimum 125 dB |
Peak Power | Maximum 10 kW |
Average Power | Maximum .60 kW |
3rd Order IM Product | Typical -125 dBm (-168 dBc) |
Mechanical | |
Mating | MIL-STD-348 |
Inner Attachment Method | Solder or captivated |
Outer Attachment Method | Compression |
Assembly Torque | 18/22 lb-ft (25/30 N-m) |
Coupling Torque | 15.00 lb-in (1.70 N-m) |
Coupling Nut Retention Force | 100.00 lbs (444.80 N) |
Connector Durability | 500 cycles, 12 cycles/minute |
Material | |
Body | Brass, silver plated |
Outer Contacts | Brass, silver plated |
Inner Contacts | Beryllium copper, gold plated |
Other Metal Parts | Brass, silver plated |
Insulators | TFE |
Gaskets | Silicone rubber |
Environmental | |
Temperature Range | Operating: -40°C to +150°C Storage: -70°C to +100°C |
Thermal Shock | MIL-STD-202, method 107, test condition A-1 |
Immersion | IEC 529, IP68 |
Vibration | MIL-STD-202, method 204, test condition B |
Corrosion | MIL-STD-202, method 101, test condition B |
Mechanical Shock | MIL-STD-202, method 213, test condition I |
Note: These characteristics are typical but may not apply to all connectors.
Electrical | |
Impedance | 50 Ω |
Frequency Range | 0-4 GHz |
Voltage Rating | 500 volts peak |
Dielectric Withstanding Voltage | 1,500 volts rms |
VSWR | M39012 straight connectors: 1.3 max @ 0-4 GHz M39012 right angle connectors: 1.35 max @ 0-4 GHz |
Insertion Loss | 0.18 dB @ 9 GHz |
Insulation Resistance | > 5,000 MΩ |
Mechanical | |
Mating | Bayonet coupling |
Braid/Jacket Cable Affixment | Hex crimp |
Center Conductor Cable Affixment | Hex crimp or solder |
Captivated Contact | Except as noted |
Cable Retention | 20-100 lbs depending on cable |
Material | |
Male Center Contact | Brass, gold plated |
Female Center Contact | Beryllium copper or phosphorous bronze, gold plated |
Other Metal Parts | Brass with bright nickel finish |
Insulators | TFE |
Weatherproof Gaskets | Silicone rubber |
Environmental | |
Temperature Range | – 65°C to + 165 °C |
Weatherproof | When mated with other Amphenol RP-BNC connectors |
Corrosion | MIL-STD-202, method 101, test condition B |
Note: These characteristics are typical but may not apply to all connectors.
Sample Part Number | S | 1 | W | N | M | PM |
Position | Position 1 | Position 2 | Position 3 | Position 4 | Position 5 | Position 6 |
Description | Corrugated Cable | Cable Diameter | Plating | Interface | Gender | Options |
Values | S=Superflex (helical) | 1=1/4″ | W=White Bronze | N=Type N | M=Male Plug | PM=Panel Mount |
A=Annular | 2=3/8″ | P=Plated Body | F=Female Jack | PM-SO=Panel Mount-Slotted Outer | ||
4=1/2″ | Blank=Not Plated | R=Right Angle Male Plug | U=Universal | |||
5=7/8″ | ||||||
6=1-1/4″ | ||||||
7=1-5/8″ |
More Information
For more information about our products, please contact us directly at 301.838.4380 or email us at sales@shireeninc.com
RFC®, Registered trademark of Shireen Inc
LMR®, Registered trademark of Times Microwave Systems
———————————————————-
FCC notice: The marketing, sale and use of power amplifiers are governed by and subject to FCC rules & regulations under Part 15.247. Shireen’s ISM band amplifiers are available for export, military, OEM & licensed customers only. It is the responsibility of the purchaser/installer/operator to insure that only approved equipment/systems are deployed. Shireen provides full engineering support to OEMs interested in certified systems.